# IP Camera Installation Checklist

## Purpose

Use this checklist for every IP camera installation to ensure consistent, professional results. Complete each section in order.

---

## Pre-Installation

<table id="bkmrk-%E2%9C%93tasknotes%E2%98%90review-si"><thead><tr><th>✓</th><th>Task</th><th>Notes</th></tr></thead><tbody><tr><td>☐</td><td>Review site drawings / camera placement plan</td><td>Confirm FOV covers target area</td></tr><tr><td>☐</td><td>Confirm camera model and lens match job specs</td><td></td></tr><tr><td>☐</td><td>Check PoE switch has available ports and power budget</td><td>PoE: 15.4W, PoE+: 30W</td></tr><tr><td>☐</td><td>Verify cable run path — no sharp bends, not near high-voltage</td><td>Max Cat6 run: 100m (328ft)</td></tr><tr><td>☐</td><td>Confirm mounting surface is structurally sound</td><td>Concrete anchor for concrete/block walls</td></tr><tr><td>☐</td><td>Have correct conduit / junction box if required</td><td></td></tr><tr><td>☐</td><td>Have correct mounting hardware (wedge mount, pendant, surface)</td><td></td></tr><tr><td>☐</td><td>Confirm camera firmware and VMS compatibility</td><td></td></tr></tbody></table>

---

## Cable Run

<table id="bkmrk-%E2%9C%93tasknotes%E2%98%90pull-cat5"><thead><tr><th>✓</th><th>Task</th><th>Notes</th></tr></thead><tbody><tr><td>☐</td><td>Pull Cat5e/Cat6 cable from IDF/MDF to camera location</td><td>Label both ends</td></tr><tr><td>☐</td><td>Test cable with cable tester before terminating</td><td>All 8 pairs, check for opens/shorts/splits</td></tr><tr><td>☐</td><td>Terminate RJ45 using T568B standard</td><td></td></tr><tr><td>☐</td><td>Punch down to patch panel at switch end</td><td>Label patch panel port</td></tr><tr><td>☐</td><td>Verify cable length does not exceed 100m total (cable + patch)</td><td></td></tr><tr><td>☐</td><td>Weatherproof cable entry if outdoors (drip loop, silicone)</td><td></td></tr></tbody></table>

---

## Mounting

<table id="bkmrk-%E2%9C%93tasknotes%E2%98%90mark-and-"><thead><tr><th>✓</th><th>Task</th><th>Notes</th></tr></thead><tbody><tr><td>☐</td><td>Mark and drill mounting holes</td><td>Use camera base as template</td></tr><tr><td>☐</td><td>Install anchors / back box as required</td><td></td></tr><tr><td>☐</td><td>Feed cable through mounting base</td><td></td></tr><tr><td>☐</td><td>Mount camera — do not overtighten</td><td></td></tr><tr><td>☐</td><td>Connect cable to camera (RJ45 or pigtail)</td><td></td></tr><tr><td>☐</td><td>Seal cable entry if outdoor installation</td><td>Use manufacturer-supplied gasket or conduit fitting</td></tr></tbody></table>

---

## Power-Up &amp; Commissioning

<table id="bkmrk-%E2%9C%93tasknotes%E2%98%90plug-into"><thead><tr><th>✓</th><th>Task</th><th>Notes</th></tr></thead><tbody><tr><td>☐</td><td>Plug into PoE switch — verify link light comes on</td><td></td></tr><tr><td>☐</td><td>Camera powers on (status LED active)</td><td>Allow 2–3 min for boot</td></tr><tr><td>☐</td><td>Camera receives IP via DHCP or set static IP per project standards</td><td></td></tr><tr><td>☐</td><td>Ping camera IP to confirm network connectivity</td><td></td></tr><tr><td>☐</td><td>Add camera to VMS (Genetec, Milestone, Exacq, etc.)</td><td></td></tr><tr><td>☐</td><td>Verify live video feed in VMS</td><td></td></tr><tr><td>☐</td><td>Adjust lens / aim to cover intended FOV</td><td>Check image in VMS, not just physically</td></tr><tr><td>☐</td><td>Configure recording schedule and retention per client requirements</td><td></td></tr><tr><td>☐</td><td>Verify recording is active and motion detection triggers correctly</td><td></td></tr><tr><td>☐</td><td>Label camera in VMS with agreed naming convention</td><td>e.g. SITE-AREA-CAM01</td></tr></tbody></table>

---

## Outdoor-Specific

<table id="bkmrk-%E2%9C%93tasknotes%E2%98%90confirm-c"><thead><tr><th>✓</th><th>Task</th><th>Notes</th></tr></thead><tbody><tr><td>☐</td><td>Confirm camera has appropriate IP66/IP67 rating for exposure</td><td></td></tr><tr><td>☐</td><td>Apply drip loop to cable before entry point</td><td></td></tr><tr><td>☐</td><td>Use conduit or corrugated loom on exposed runs</td><td></td></tr><tr><td>☐</td><td>Tighten all weatherproof fittings / gaskets</td><td></td></tr><tr><td>☐</td><td>Check for IR reflection from nearby surfaces (night mode)</td><td></td></tr></tbody></table>

---

## Final Sign-Off

<table id="bkmrk-%E2%9C%93tasknotes%E2%98%90all-camer"><thead><tr><th>✓</th><th>Task</th><th>Notes</th></tr></thead><tbody><tr><td>☐</td><td>All cameras visible in VMS with correct names</td><td></td></tr><tr><td>☐</td><td>Recording confirmed on all cameras</td><td></td></tr><tr><td>☐</td><td>No loose cables or exposed wire runs</td><td></td></tr><tr><td>☐</td><td>Cleanup completed — packaging, scrap cable disposed</td><td></td></tr><tr><td>☐</td><td>Document IP addresses, MAC addresses, port assignments</td><td></td></tr><tr><td>☐</td><td>Client walkthrough completed if required</td><td></td></tr></tbody></table>